High Performance
adopts high-end imported sensors from different countries
real-time detection and one-click query of the concentration curve
up to 4 particle channels, PM0.5, PM1.0, PM2.5, PM10
|

|
Variety Signal Output :
• RS485 standard, 4-20mA signal converter optional
1-2 relays output
• multiple transmission options: 3-4 core cable, optical
fiber network, network cable, wireless transmission
• multiple data receiving modes: PC, gas alarm
controller, PLC, DCS, mobile phone,etc.
|

|

|
Meet the Requirements of Different Industries
• optional gas pretreatment system for complex environment
• variety installation type: wall mounting
• infrared remote control is optional to operate in dangerous situations without opening the lid
|
|
Dust Detection:
|
Dust Particle, Laser dust sensor (0.3/0.5um,1.0um,2.5um,10um)
|
|
Detection Range:
|
0-999ug/m3; 0-9999999PC/L
|
|
Resolution:
|
1ug/m3; 1PC/L
|
IP Rating :
|
IP66
|
|
Response Time:
|
≤20S(T90)
|
Detection Accuracy:
|
≤±5% (Depending on the specific sensor)
|
|
Linearity Error:
|
≤±1%
|
Zero Drift:
|
≤±1%(F.S/Year)
|
|
Recovery Time:
|
≤20S(T90)
|
Scalable Gas Sensor:
|
User can customize 1-6 gas sensors in any combination
|
|
Repeatability:
|
≤±1% F.S
|
Explosion Proof Sign:
|
CNEx16.0547
|
|
Temperature & Humidity(optional function):
|
temperature detection range:-40 ~ 120℃
humidity detection range:0-100%RH
|
|
Detection Pattern:
|
diffusion, online detection
|
|
Installation Method:
|
wall mounting type
|
|
Signal Output:
|
① 4-20mA signal (optional): standard 16bit 4-20mA output chip, transmission distance 1Km
② RS485 signal: standard MODBUS RTU protocol, transmission distance 2Km
③ 0-5V,0-10V output are optional
④ 1-2 relays output: Concentration alarm value adjustable contact rating:24VDC; 3A/220VAC 3A
|
|
Transmission Mode:
|
① Cable transmission :3-core, 4-core cable, long distance transmission (1-2 km)
② TCP/IP transmission: supporting TCP/IP protocol, using optical fiber, network cable, long-distance real-time transmission via intranet and extranet network (optional)
③ GPRS transmission: built-in GPRS module, real-time remote transmission of data, not limited by distance (optional)
④ Wireless transmission: supporting 433MHz, radio transmission mode, transmission distance 2-10Km, depending on power (optional)
|
|
Data Receiving Device :
|
PC, Gas Alarm Controller, PLC, DCS, Mobile Phone and Tablet Computer is optional
|
|
Alarm Mode:
|
audible and visual alarm, external alarm, remote controller alarm, computer data acquisition software alarm, mobile phone APP notification, SMS alarm are optional
|
|
Alarm Setting:
|
①standard configuration two-level alarm, three-level alarm is optional
②two alarm mode:high alarm & low alarm mode, interval control alarm mode
③interval control alarm for temperature sensor
④interval control alarm for humidity sensor
|
|
Material:
|
aluminum, explosion and corrosion proof
|
|
Working Environment:
|
Operating Temperature: -30℃ ~ 50℃)Higher temperature and humidity require custom sensors or optional preprocessing systems
Relative Humidity: ≤90%RH,Non-condensing
Pressure: 0 ~ 100Kpa
Power : 24VDC(12~30VDC)
Connection: 3/4″NPT,1/2″NPT, two connection modes are supported at the same time
|
|
Dimensions:
|
183*191*80mm(L×W×H) 1.5Kg(Net weight)
|
|
Standard Accessories:
|
User manual, certificate, calibration cover
|